Install the Right Steer Hose
Disconnect the existing right steer line from the steering orbitrol.
1.
Install the supplied -8 ORFS run tee fitting (P/N 333-0012-028) and reconnect the original pressure hose to
2.
the straight portion of the fitting.
Connect the 90° end of the supplied hose (P/N 214-1000-663) to the remaining branch of the tee fitting.
3.
Machine's Steering Orbitrol
FIGURE 7.
Right Steer
Connection
Route the other end of the hose to Port 'B' of the SmarTrax hydraulic valve using a supplied -6 ORFS 45°
4.
fitting (P/N 333-0012-090) or a supplied -6 ORFS 90° fitting (P/N 333-0012-065) if necessary.
SmarTrax Hydraulic Valve
FIGURE 8.
Manual No. 016-4001-023
Hydraulic Connections
'B' Port
15