Chapter 4

Install the Pressure Hose

Disconnect the existing pressure hose from the steering orbitrol.
1.
Install the supplied -8 ORFS run tee fitting (P/N 333-0012-028) and reconnect the original pressure hose to
2.
the straight portion of the fitting.
Connect the 90° end of the supplied hose (P/N 214-1000-664) to the remaining branch of the tee fitting.
3.
Pressure Hose Installed
FIGURE 1.
Pressure
Route the other end of the hose to Port 'P' of the SmarTrax hydraulic valve using a supplied -6 ORFS 45°
4.
fitting (P/N 333-0012-090) or a supplied -6 ORFS 90° fitting (P/N 333-0012-065) if necessary.
SmarTrax Hydraulic Valve
FIGURE 2.
12
The appearance of the SmarTrax hydraulic
valve may vary slightly from the images
contained in this manual. However, the fittings,
hose connections, and cable connections
remain the same.
CaseIH FLX 4010, 4020, 4510, and 4520 SmarTrax Installation Manual