Needle Valve Hose

Attach the Needle Valve to Tank hose to the remaining open port of the tee on the Tank port of the
orbital. Attach the other end to the open port on the needle valve. It may be necessary to use one of
the provided elbow fittings to ensure the tee is routed properly.

CB to Right Steer Hose

Remove the hose attached to the Right Steer port of the orbital. Connect the proper-sized end of the
CB to Right Steer hose to the open Right Steer port on the orbital. Connect the other end to the "B"
port on the side of the counterbalance valve with the Brake port. User may wish to install an elbow
fitting on the counterbalance valve to properly route the new hose.

CB to Left Steer Hose

Remove the hose attached to the Left Steer port of the orbital. Connect the proper-sized end of the
CB to Left Steer hose to the open Left Steer port on the orbital. Connect the other end to the "A" port
on the side of the counterbalance valve with the Brake port. User may wish to install an elbow fitting
on the counterbalance valve to properly route the new hose.