Reduced oil capacity open fryer (gas)

Advertisement

Reach around the module box housing and remove the last 7/16" bolt from the
1 1 3 3 ) )
motor bracket.
Remove the hubmounted filter pump and motor assembly.
1 1 4 4 ) )
6 6 . . 1 1 7 7 . . 2 2 I I n n s s t t a a l l l l i i n n g g t t h h e e H H u u b b m m o o u u n n t t e e d d F F i i l l t t e e r r P P u u m m p p a a n n d d M M o o t t o o r r
A A s s s s e e m m b b l l y y
Place the hubmounted filter pump and motor assembly on the motor bracket
1 1 ) )
and feed the wires back into the motor.
Connect the M1 terminal connector to terminal 1 and the M2 terminal connector
2 2 ) )
to terminal 4.
Tighten the conduit connector.
3 3 ) )
Reinstall motor access panel onto motor.
4 4 ) )
Remove ignition box from bungee cord and reinstall using 3/8" wrench.
5 5 ) )
Finger thread the three 7/16" bolts into the motor bracket. (Do not tighten)
6 6 ) )
Attach and hand tighten the flexible line fitting and plug and play connection.
7 7 ) )
Reinstall plug and play support bracket, finger tightening the two 3/8" nuts.
8 8 ) )
Slide in drain pan until it latches to ensure proper plug and play and drain pan
9 9 ) )
alignment.
Pull the motor towards the front of the fryer as far as possible.
1 1 0 0 ) )
Tighten the three motor bolts, plug and play compression fitting, flexible line
1 1 1 1 ) )
fitting, and nuts on plug and play bracket.
59