Download Print this page

Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 14

Reduced oil capacity open fryer (gas)

Advertisement

Problem
Oil will not
drain from
vat.
Filter motor
runs but
pumps oil
slowly.
Bubbles in
oil during
entire filter-
ing
process.
Filter motor
will not run.
2
Cause
Improper filtering.
Refer to filtering procedures.
Improper rinsing
Clean and rinse vat and then dry thoroughly.
after cleaning the
vat.
Drain valve
Open valve, force cleaning brush through drain.
clogged with
crumbs.
Filter line connec-
Tighten all filter line connections.
tions loose.
Filter paper or
Change filter paper or pad.
pad clogged.
Filter not reas-
Refer to assembly instruction on inside door.
sembled
correctly.
Filter pan not
Make sure filter pan return line is pushed completely into
completely
the receiver on the fryer.
engaged.
Filter pan
Clean pan and change paper or pad.
clogged.
Damaged O-ring
Replace O-ring.
on filter line re-
ceiver on fryer.
Thermal reset
Allow motor to cool, then, using a screwdriver, press hard
button on the rear
against the button until it clicks.
of the pump mo-
tor is tripped.
T T o o p p r r e e v v e e n n t t b b u u r r n n s s c c a a u u s s e e d d b b y y s s p p l l a a s s h h i i n n g g s s h h o o r r t t e e n n i i n n g g , ,
t t u u r r n n t t h h e e u u n n i i t t ' ' s s p p o o w w e e r r s s w w i i t t c c h h t t o o t t h h e e o o f f f f p p o o s s i i t t i i o o n n b b e e f f o o r r e e
r r e e s s e e t t t t i i n n g g t t h h e e f f i i l l t t e e r r p p u u m m p p m m o o t t o o r r ' ' s s m m a a n n u u a a l l r r e e s s e e t t p p r r o o t t e e c c - -
t t i i o o n n d d e e v v i i c c e e . .