Download Print this page

Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 15

Reduced oil capacity open fryer (gas)

Advertisement

1 1 . . 3 3 E E r r r r o o r r C C o o d d e e s s
In the event of a control system failure, the digital display shows an error message.
The message codes are shown in the display column below. A constant tone is heard
when an error code is displayed, and to silence this tone, press any button.
Display
Cause
E-4
Control board
overheating.
E-5
Oil overheating.
E-6A
Temperature probe
open.
E-6B
Temperature probe
shorted.
E-10A
High limit tripped
above 300°F
E-10B
High limit tripped
below 300°F
E-10C
High limit tripped
while cooking
E-10D
High limit tripped <5
min of Auto Filter
E-10F
High limit tripped
during filter cycle
E-10M
High limit tripped
during melt mode
E-10Y
High limit tripped <5
min of YES
E-15
Drain switch.
E-18A
Left level sensor
open.
E-18B
Right level sensor
open.
E-18C
Both level sensors
open.
T T a a b b l l e e 1 1 - - 2 2 E E r r r r o o r r C C o o d d e e s s
Panel Board Correction
Turn switch to off position, then turn switch back to
on; if display shows "E-4", the control board is getting
too hot; check the louvers on each side of the unit for
obstruction.
Turn switch to off position, then back to on; if display
shows "E-5", the heating circuits and temperature
probe should be checked.
Turn switch to off position, then back to on; if the dis-
play shows "E-6", the temperature probe should be
checked.
Let the unit cool down (15-20 minutes), push up on
metal reset button under right side of the controls; if
high limit does not reset, high limit must be replaced.
Make sure drain knob is completely pushed-in; if "E-
15" persists, have drain switch checked.
Turn switch to off position, then back to on; if display
still indicates a failed sensor, have the connections
checked on the control board. Have sensor check
and replaced if necessary.
3

Advertisement

loading

This manual is also suitable for:

Wendy’s evolution elite eeg-254