Download Print this page

Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 26

Reduced oil capacity open fryer (gas)

Advertisement

3 3 . . 1 1 . . 9 9 C C P P U U T T e e m m p p e e r r a a t t u u r r e e
Press the right arrow and "9.CPU TMP" shows in the left display and the current
1 1 ) )
PC board temperature displays.
3 3 . . 1 1 . . 1 1 0 0 C C O O M M M M M M C C
Press the right arrow and "10.COM MMC" displays.
1 1 ) )
3 3 . . 1 1 . . 1 1 1 1 A A n n a a l l o o g g
Press the right arrow and "11.ANALOG" displays.
1 1 ) )
3 3 . . 1 1 . . 1 1 2 2 A A c c t t i i v v i i t t y y L L o o g g
Press the right arrow and "12.ACT LOG" displays.
1 1 ) )
3 3 . . 1 1 . . 1 1 3 3 O O i i l l L L e e v v e e l l s s
Press the right arrow and "13.OIL LVL" displays.
1 1 ) )
3 3 . . 1 1 . . 1 1 4 4 P P u u m m p p s s a a n n d d V V a a l l v v e e s s
Press the right arrow and "14.PUMPS VALVES" displays.
1 1 ) )
For selector valve information, press the down arrow button 3 times. "SEL
2 2 ) )
VALVE" displays.
To calibrate the selector valve, press product button 3 and the left ✓ button. The
selector valve will make 3 revolutions and returns to the home position. Successful
calibration is 2.00R 10P E/R2000 +/- S
To move the selector valve one position forward, press product button 4 and the left ✓
button. Continue to press the left ✓ button to move the selector valve forward one
position.
To set the selector valve on continuous run, press product button 5 and the left ✓
button. Pressing the left ✓ button again ends the continuous run and the selector
valve returns to the home position.
3 3 . . 1 1 . . 1 1 5 5 A A I I F F I I n n f f o o
Press the right arrow and "15.AIF INFO" displays.
1 1 ) )
3 3 . . 1 1 . . 1 1 6 6 U U S S B B S S u u p p p p o o r r t t
Press the right arrow and "16.USB" SUPPORT" displays.
1 1 ) )
Press the down arrow and REPORTS NO DRIVE displays.
2 2 ) )
Insert USB drive into USB port. PRINT displays.
3 3 ) )
Press the ✓ button. The right display cycles through the reports and logs. When
4 4 ) )
the upload is complete, *REPORT* *DONE* displays.
When REMOVE USB? displays in the left display, press the ✓ button. WAIT
5 5 ) )
displays.
Once OK TO REMOVE displays, you can remove the USB drive.
6 6 ) )
Insert USB drive into USB port on laptop or desktop computer.
7 7 ) )
Navigate to the USB file folder on the computer.
8 8 ) )
Open the spreadsheet file to review the report.
9 9 ) )
14