Reduced oil capacity open fryer (gas)

Advertisement

Cut zip ties that are holding the wires to the blower. Remove the wirenuts from
4 4 ) )
the wires.
Remove blower.
5 5 ) )
Reconnect new blower wires to the existing wires with wirenuts.
6 6 ) )
Tighten the new blower onto the flue with the two screws.
7 7 ) )
Zip tie wires back to the blower.
8 8 ) )
6 6 . . 1 1 3 3 B B l l o o w w e e r r W W h h e e e e l l R R e e p p l l a a c c e e m m e e n n t t
Refer to images in
6.11 Blower Cleaning , page 50
W W A A R R N N I I N N G G ! ! S S H H O O C C K K H H A A Z Z A A R R D D T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , ,
m m o o v v e e t t h h e e p p o o w w e e r r s s w w i i t t c c h h t t o o O O F F F F a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r u u n n p p l l u u g g
c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
Loosen set screw using a hex-key.
1 1 ) )
Attach wheel puller to OD of wheel hub by tighten 3 hex head bolts down with 1/
2 2 ) )
2" wrench, making sure to keep the puller centered along the wheel/shaft axis.
Turn screw to remove the wheel from the motor shaft.
3 3 ) )
File down the burr on the shaft left by the set screw, to allow wheel to slide onto
4 4 ) )
shaft freely.
Install wheel with hub set to end of shaft and tighten set screw.
5 5 ) )
Turn on blower and verify that pressure is 1.7 inwc at 60 Hz (1.4 inwc at 50 Hz)
6 6 ) )
or greater.
If less than 1.7 inwc at 60 Hz (1.4 inwc at 50 Hz) verify that flue is not obstructed and
clean as needed to achieve 1.7 inwc.
6 6 . . 1 1 4 4 R R e e s s e e t t t t i i n n g g t t h h e e T T h h e e r r m m a a l l O O v v e e r r l l o o a a d d S S w w i i t t c c h h
The two most common causes of a pump malfunction are the pump is clogged or the
thermal overload switch on the motor has been tripped. The pump and motor
assembly are located on the rear of the fryer.
To reset the thermal overload switch:
for visual reference.