Reduced oil capacity open fryer (gas)

Advertisement

• Press product button 1 to open and close the bulk oil discard valve (display
shows "DISCARDo" when open).
• Press product button 2 to open and close the bulk oil JIB fill valve (display
shows "JIBFILLo" when open).
Press the down arrow for selector valve calibration, index, or continous run.
4 4 ) )
• Press product button 3 and then press the left timer 1 button to calibrate the
selector valve. The selector valve will rotate until it is at home position, port
10.
• Press product button 4 and then press the left timer 1 button to index, or
rotate through each position of the selector valve. NEXT POS AT 9 indicates
the valve is in the JIB fill position. NEXT POS AT 10 indicates the valve is in
the home position.
• Press product button 5 and then press the left timer 1 button to set the
selector valve on continuous run. Press left timer 1 button again to end
continuous run.
Press the down arrow and "PUMP FP_" and "JP_ NP_" shows in the displays
5 5 ) )
(Driven by the AIF board).
• Ensure return or discard valve is open and press product button 1 to turn off
and on the filter pump (display shows "FP*" when on).
• Ensure return valve is open and press product button 2 to turn off and on the
JIB pump (display shows "JP*" when on).
• Ensure return or JIB fill valve is open and press product button 3 to turn off
and on the new oil pump (if available - display shows "NP*" when on).
5 5 . . 6 6 S S t t a a t t s s M M o o d d e e
This mode allows a technician to view advanced information on the operation of the
fryer and controls.
Press and hold the program button for 5 seconds until "LEVEL 2", followed by,
1 1 ) )
"SP PROG" and "ENTER CODE" show in the display.
Press the program button 5 times and "STATS" and "ENTER CODE" flash in the
2 2 ) )
left display.
Enter code 1, 1, 2, 2, 1, 1, 2, 2 (first 2 product buttons).
3 3 ) )
"ST-1 STATS LAST RESET ON..." flashes in the left display and the date shows
4 4 ) )
in the right display. Use the up or down arrow to select the steps.
N N O O T T E E : : :
• If a bad code is entered, a tone sounds and "BAD CODE" shows on the
display. Wait a few seconds, the controls revert back to the cook mode, and
repeat the above steps.
• Press and hold the program button at anytime to return to normal operation.
• ST-1 Stats Last Reset Date
• ST-2 Fryer Total Running Hours
• ST-3 Left Vat Melt Cycle Hours