Download Print this page

Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 34

Reduced oil capacity open fryer (gas)

Advertisement

To reset the controls to factory default settings, press and hold the ✓ button and
2 2 ) )
controls count down "IN 3", "IN 2", "IN 1". Once the display shows "-INIT-" and
"*DONE*", the controls are reset to factory defaults.
5 5 . . 1 1 . . 4 4 S S P P - - 4 4 A A u u d d i i o o V V o o l l u u m m e e
Press and release the right arrow until "SP-4" "VOLUME" flashes in the left
1 1 ) )
display.
Press the up or down arrow, or product buttons, to adjust the speaker volume,
2 2 ) )
10 being loudest and 1 being the most quiet.
5 5 . . 1 1 . . 5 5 S S P P - - 5 5 A A u u d d i i o o T T o o n n e e
Press and release the right arrow until "SP-5" "TONE" flashes in the left display.
1 1 ) )
Press the up or down arrow button, or product buttons, to adjust the tone of the
2 2 ) )
speaker, 2000 being the maximum value and 50 being the minimum.
5 5 . . 1 1 . . 6 6 S S P P - - 6 6 M M e e l l t t C C y y c c l l e e S S e e l l e e c c t t i i o o n n
Press and release the right arrow until "SP-6 MELT CYCLE SELECT" scrolls in
1 1 ) )
the left display. Unless solid oil is being used in the vats, the right display should
show "1.LIQUID".
If solid shortening is used, the unit must be equipped to handle solid oil.
2 2 ) )
Use the up or down arrow to change the right display to "2.SOLID".
3 3 ) )
5 5 . . 1 1 . . 7 7 S S P P - - 7 7 I I d d l l e e M M o o d d e e E E n n a a b b l l e e d d
An Idle Mode allows the oil temperature to drop to a lower temperature when not in
use. This saves on oil and utilities.
Press and release the right arrow until "SP-7" "IDLE MODE ENABLED?" flashes
1 1 ) )
in the left display.
Press the up or down arrow to choose "YES" or "NO".
2 2 ) )
With "YES" in the display, press the right arrow and "SP-7A" "USE '0' FOR
3 3 ) )
IDLE" flashes on the left display. Press the up or down arrow to select "YES" or
"NO". If "YES" is selected, an Idle Mode can be programmed in product button
0.
Press the right arrow and "SP-7B" "AUTOIDLE MINUTES" flashes in the left
4 4 ) )
display.
Press the up or down arrow, or use the product buttons, to set the time (0 to 60
5 5 ) )
minutes) fryer stays idle before auto-idle is enabled. Ex., "30" means, if product
is not cooked in that vat for 30 minutes, the control automatically cools the oil
down to the idle set-point temperature.
Press the right arrow and "SP-7C" "IDLE SETPT" flashes in the left display.
6 6 ) )
Press the up or down arrow, or use the product buttons, to set idle temperature
7 7 ) )
200°F to 375°F (93°C to 191°C).
5 5 . . 1 1 . . 8 8 S S P P - - 8 8 F F i i l l t t e e r r T T r r a a c c k k i i n n g g M M o o d d e e
Filter Tracking signals the operator when the oil needs filtering by counting the
number of Cook Cycles between filters.