Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 75

Reduced oil capacity open fryer (gas)

Advertisement

Remove the two screws securing the pilot to the burner assembly (2). The right
5 5 ) )
hand screw will have the ground wire.
While using a 1/2" wrench to hold the base of the pilot orifice (4), use a 7/16 inch
6 6 ) )
wrench to loosen the pilot tube (5) from the pilot.
Disconnect the flame sensor.
7 7 ) )
Replace pilot in reverse order.
8 8 ) )
NOTICE When screwing the pilot back into the burner assembly, be sure to
connect the ground wire to the right hand screw.