Reduced oil capacity open fryer (gas)

Advertisement

Press the up or down arrow, or product buttons, to select the desired 2nd
2 2 ) )
volume.
NOTE: Be setting a 2nd volume in the controls, 2 volumes can now be chosen by
pressing the program button twice during normal operation. One volume setting
shows in the left display (NONE to 10; 10 being the loudest) and the seconds volume
shows in the right display. To select the volume, press the ✓ button under the desired
volume.
5 5 . . 1 1 . . 1 1 8 8 S S P P - - 1 1 8 8 E E n n e e r r g g y y S S a a v v e e M M o o d d e e
Press and release the right arrow until "SP-18 ENERGY SAVE ENABLED?"
1 1 ) )
flashes in the left display.
Press the up or down arrow to choose "YES" or "NO".
2 2 ) )
If set to "YES", during times of non-use, the fryer automatically starts an Energy
3 3 ) )
Save Mode, which turns off the blowers. Then once a product is selected to start
a cook cycles, the blowers and heat come back on. If set to "NO", the blowers
are on constantly.
5 5 . . 1 1 . . 1 1 9 9 S S P P - - 1 1 9 9 F F r r y y e e r r T T y y p p e e
Press and release the right arrow until "SP-19 FRYER TYPE" flashes in the left
1 1 ) )
display.
Press the up or down buttons to choose "GAS" or "ELEC".
2 2 ) )
5 5 . . 1 1 . . 2 2 0 0 S S P P - - 2 2 0 0 V V a a t t T T y y p p e e
Press and release the right arrow until "SP-20 VAT TYPE" flashes in the left
1 1 ) )
display.
Press the up or down arrow to choose "SPLIT" or "FULL".
2 2 ) )
5 5 . . 1 1 . . 2 2 1 1 S S P P - - 2 2 1 1 A A u u t t o o - - L L i i f f t t E E n n a a b b l l e e d d
Press and release the right arrow until "SP-21 AUTOLIFT ENABLED?" flashes
1 1 ) )
in the left display.
Press the up or down arrow to choose "YES LIFT" or "NO LIFT".
2 2 ) )
If fryer is fitted with the auto-lift option, SP-21 must be set to "YES LIFT",
3 3 ) )
otherwise, set SP-21 to "NO LIFT".
5 5 . . 1 1 . . 2 2 2 2 S S P P - - 2 2 2 2 B B u u l l k k O O i i l l S S u u p p p p l l y y
Press and release the right arrow until "SP-22 BULK OIL SUPPLY?" flashes in
1 1 ) )
the left display.
Press the up or down arrow to choose "YES SUPL" or "NO SUPL".
2 2 ) )
Set to "YES" if the oil is pumped into the vat from an outside oil reservoir.
3 3 ) )
Otherwise, set SP-22 to "NO".
5 5 . . 1 1 . . 2 2 3 3 S S P P - - 2 2 3 3 B B u u l l k k O O i i l l D D i i s s p p o o s s a a l l
Press and release the right arrow until "SP-23 BULK OIL DISPOSE?" flashes in
1 1 ) )
the left display.
Press the up or down arrow to choose "YES DISP" or "NO DISP".
2 2 ) )
Set to "YES DISP" if the oil is pumped from the vats to an outside oil reservoir
3 3 ) )
when discarding the oil. Otherwise, set SP-23 to "NO DISP".