Download Print this page

Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 57

Reduced oil capacity open fryer (gas)

Advertisement

and "PUMP" "EXIT" shows in the display. Press ✓ again, and oil fills form vat.
Once vat is full, press X X twice to return to normal operation.
6 6 . . 8 8 S S o o l l e e n n o o i i d d V V a a l l v v e e s s
Each vat has a solenoid plumbed-into the oil return lines. They are normally closed,
but open when power is supplied, such as, the controls are filling the vats.
T T o o a a v v o o i i d d e e l l e e c c t t r r i i c c a a l l s s h h o o c c k k o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e , , m m o o v v e e t t h h e e
p p o o w w e e r r s s w w i i t t c c h h t t o o o o f f f f a a n n d d d d i i s s c c o o n n n n e e c c t t m m a a i i n n c c i i r r c c u u i i t t b b r r e e a a k k e e r r , , o o r r
u u n n p p l l u u g g c c o o r r d d a a t t w w a a l l l l r r e e c c e e p p t t a a c c l l e e . .
6 6 . . 8 8 . . 1 1 S S o o l l e e n n o o i i d d V V a a l l v v e e C C h h e e c c k k o o u u t t
Remove both top and bottom rear panels, or a side panel depending upon the
1 1 ) )
location of the solenoid.
Follow the wires from the solenoid and through the conduit then loosen lever
2 2 ) )
nuts to release wires. Strip wires back and take an ohm reading.
120 Volts - 60 Hz
220-240 Volts - 50/60 Hz
6 6 . . 8 8 . . 2 2 S S o o l l e e n n o o i i d d V V a a l l v v e e R R e e p p l l a a c c e e m m e e n n t t
Using an adjustable wrench, loosen the front and rear fittings to solenoid (1).
1 1 ) )
Remove the conduit (2) from the fryer and pull the solenoid assembly form the
2 2 ) )
fryer.
Follow conduit wires to side panel and remove side panel.
3 3 ) )
Release conduit wires from lever nuts.
4 4 ) )
Remove the conduit from the side channel and solenoid.
5 5 ) )
Test Point
Ohm Reading
50 Ohms
230 Ohms
45

Advertisement

loading

This manual is also suitable for:

Wendy’s evolution elite eeg-254