Henny Penny Wendy’s Evolution Elite EEG-253 Service Manual page 44

Reduced oil capacity open fryer (gas)

Advertisement

5 5 . . 5 5 . . 7 7 T T - - 7 7 D D e e c c i i m m a a l l P P o o i i n n t t s s T T e e s s t t
Press timer button 1 to view all decimal points across the displays.
1 1 ) )
5 5 . . 5 5 . . 8 8 T T - - 8 8 L L E E D D ' ' s s T T e e s s t t
Press timer 1 to view each LED across the control panel.
1 1 ) )
5 5 . . 5 5 . . 9 9 T T - - 1 1 7 7 I I n n p p u u t t s s - - H H D D F F
H = HIGH LIMIT - If "H" is present, the high limit is good. If "-" shows then the high limit
is tripped out (overheated) or disconnected.
D = DRAIN SWITCH - If "D" is present, the drain handle (when applicable) is closed. If
"-" shows then the drain is open or the switch is faulty.
F = FAN (PRESSURE SWITCH) - If "F" is present, the pressure witch is good. If "-"
shows in the display, the switch is faulty.
Press the down arrow and an underscore ("_") indicates the input is not
1 1 ) )
presently detected. A checkmark ("√" ) indicates the signal is detecting a normal
input. A blinking ("X") indicates the signal is presently detected, but is detected
as a half-wave (partially failed) input.
NOTE: The H, D, F signals above are wired in series. The first signal missing out of
this sequence l generally causes all signals to the right of it to be missing as well.
5 5 . . 5 5 . . 1 1 0 0 T T - - 1 1 8 8 A A I I F F I I n n f f o o ( ( A A I I F F P P C C B B C C o o m m m m u u n n i i c c a a t t i i n n g g W W i i t t h h C C o o n n t t r r o o l l
P P C C B B ? ? ) )
An "AIF ✓" means normal communications between the AIF PCB and the control
PCB. "AIF X X " means a problem with the communications between the PCBs.
5 5 . . 5 5 . . 1 1 1 1 T T - - 1 1 9 9 O O u u t t p p u u t t s s
S = SAFETY GAS VALVE (if available) - Press product button 7 to open and close the
gas safety valves.
H = HEAT OUTPUTS - Press product button 9 to turn the heating outputs (ex: gas
valve) on and off .
Press the right arrow and "7. OUTP" and "F-S-I-H-" display.
1 1 ) )
• F = FAN (PRESSURE SWITCH) - F- = fan de-energized; off, F* = fan energized,
pressure switch open; on F.* = fan energized, pressure switch closed; on.
• S = SAFETY GAS VALVE (if available) - S- safety gas valve de-energized; closed S*
safety gas valve energized; open
• I = IGNITION MODULE - I- ignition module de-energized; close, I* ignition module
energized without pilot flame sense; open, I.* ignition module energized with pilot
flame sense; open.
32
Full vat — Press product button 6 to turn the burner fan on and off.
Left split vat — Press product button 1 to turn the burner fan on and off..
Right split vat — Press product button 6 to turn the burner fan on and off.
Full vat — Press product button 7 to open and close the safety gas valve.
Left split vat — Press product button 2 to open and close the safety gas valve.
Right split vat — Press product button 7 to open and close the safety gas valve.