Subfault: 32.8
Description: User-timeout timeout
Response: User timeout timeout response
The timeout time of the user timeout function
elapsed
Subfault: 32.11
Description: Local mode timeout
Response: Local mode – timeout response
Communication connection to device interrupted
in local mode.
New Scope project created.
Scope measurement loaded from device.
Subfault: 32.12
Description: Manual mode timeout
Response: Manual mode – timeout response
Communication connection to device interrupted
in manual mode.
New Scope project created.
Scope measurement loaded from device.
8.6.26
Fault 33 System initialization
Subfault: 33.1
Description: Motor current measurement
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Motor current measurement detected an error.
Cause
Cause
Cause
Cause
Measure
Write the parameter for triggering the user
timeout function cyclically before the timeout time
elapses.
Measure
– Increase the timeout setting in local mode.
– Reset the fault.
– Restart local operation.
– Reset the fault.
– Restart local operation.
Measure
– Check whether too many programs are open on
the operator PC.
– Increase the timeout time in manual mode.
– Reset the fault.
– Restart manual mode.
– Reset the fault.
– Restart manual mode.
Measure
Contact the SEW‑EURODRIVE Service.
Operating Instructions – MOVIMOT
Service
8
Fault/error table
243
®