Shock load
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Climatic environmental conditions
Long-term storage in the transport packaging
Transport in the transport packaging
Operation
Table 2- 3
Certificates
Declarations of Conformity
Approvals
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
Class 1M2 according to EN 60721-3-1
Class 2M3 according to EN 60721-3-2
Test values: 15 g / 11 ms
Class 1K4 according to EN 60721-3-1
Temperature: -25°C ... +55°C
Class 2K4 according to EN 60721-3-2
Temperature: -40°C ... +70°C
better than Class 3K3 according to EN 60721-3-3
Temperature: 0 °C ... +40 °C
Relative humidity: 5 % ... 95 % (no condensation)
Oil mist, salt mist, ice formation, condensation, dripping water,
spraying water, splashing water and water jets are not permit-
ted
CE
cURus