10.2.6

Protective conductor connection and shield support

Shield contacts are only required if the system is connected to X521/X531.
Figure 10-8
The bending radii of the cables must be taken into account (see MOTION-CONNECT
description).
NOTICE
Damage or faulty operation due to incorrect shielding or inadmissible cable lengths
If the correct shielding procedures or the permissible cable lengths are not observed, it can
cause damage or the machine may malfunction.
• Only use shielded cables.
• Do not exceed the cable lengths stated in the technical data.
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
Protective conductor connection M4 / 1.8 Nm
Shield connection terminal, Weidmüller company, type: KLBÜ CO1, Article No.: 1753311001
Shield support and protective conductor connection
Encoder system connection
10.2 Sensor Module Cabinet-Mounted SMC30
257