Specifications For Use With Ul Approval - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
9.3.7

Specifications for use with UL approval

Pre-assembled cables
Sensor/actuator cable, 5-pin, variable cable,
free cable end at straight socket M12-SPEEDCON,
cable length: 2, 5, 10, 15 m
SAC-5P-...-186/FS SCO
Up to 100 m on request
Phoenix Contact
Cables to be assembled by the user
Cable
Cable coil, black PUR/PVC, 5-pin
Conductor colors:
brown/white/blue/black/gray
Cable length: 100 m
SAC-5P-100.0-186/0.75
Article number: 1535590
Phoenix Contact
Power supply
The DME20 must use one of the following 24 V power supplies with voltage limiting:
● SITOP 6EP1x.. or 6ES7307..
● SINAMICS Control Supply Module 6SL3100-1DE22-0A...
Cable pin assignment
Table 9- 24
Connection to X524 electronics power supply
Pin
1 (brown)
2 (white)
3 (black)
4 (blue)
5 (gray)
The colors refer to the cable specified above
1)
236
Designation
Electronics power supply
1)
Electronics power supply
1)
Electronics ground
1)
Electronics ground
1)
Not connected internally
1)
Connector
Sensor/actuator connector, socket, straight, 5-pin,
M12, A-coded
Screw connection, metal knurl,
cable gland Pg9
SACC-M12FS-5CON-PG9-M
Article number: 1681486
Technical data
The supply voltage of 20.4 V ... 28.8 V refers to the
(terminal) voltage at the DME20. This must be taken
into account when selecting the cable cross-section
and supply cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
SINAMICS S120 Combi