B—Hazard distance. Operators must control access to the beam within the hazard distance or
install the product preventing potential exposure of the spectators' eyes from being in the
hazard distance.
•
C—No access zone. Horizontal clearance of the no access zone must be a minimum of 2.5
meters.
•
D—Vertical distance to hazard zone. The hazard zone must be no lower than 3.0 meters above
the floor.
•
E—Represents the top view of the projector.
•
F—Represents the side view of the projector.
For US and international hazard distances based upon IEC 62471-5:2015, Photobiological Safety of
Lamps and Lamp Systems – Part 5: Image Projectors.
Projection lens
0.72:1 HB fixed
0.9:1 HB fixed
1.13-1.31:1 HB zoom
1.13-1.66:1 HB zoom
1.31-1.63:1 HB zoom
1.45-2.17:1 HB zoom
1.63-2.17:1 HB zoom
1.95-3.26:1 HB zoom
1.99-2.71:1 HB zoom
2.71-3.89:1 HB zoom
3.89-5.43:1 HB zoom
0.72:1 UHC fixed
0.9:1 UHC fixed
1.13-1.66:1 UHC zoom
1.45-2.17:1 UHC zoom
1.95-3.26:1 UHC zoom
2.71-3.89:1 UHC zoom
3.89-5.43:1 UHC zoom
For Installations in the United States
The following must be in place for laser-illuminated projector installations in the United States:
•
Any human access to the hazard zone, if applicable, must be restricted by barriers to enforce
the no access zone.
•
Permanent show installations containing Risk Group 3 laser-illuminated projectors must meet
the following conditions:
4K40-RGB Series Service Guide–D4K40-RGB, Roadie 4K40-RGB, Mirage 4K40-RGB
020-102960-02 Rev. 1 (12-2019)
Copyright
2019 Christie Digital Systems USA, Inc. All rights reserved.
©
Part number
Hazard distance
(m)
144-110103-XX
1.0
144-111014-XX
1.0
144-103105-XX
1.0
144-129103-XX
2.0
144-104106-XX
2.0
144-130105-XX
2.5
144-105107-XX
2.5
144-131106-XX
4.0
144-106108-XX
3.0
144-107109-XX
4.5
144-108100-XX
6.5
163-116109-XX
1.0
163-117100-XX
1.0
163-118101-XX
2.0
163-119102-XX
2.5
163-120103-XX
3.5
163-121105-XX
4.6
163-122106-XX
6.6
Service guidelines