WATANABE G1000 Series Instruction Manual page 86

Graphic multi-meter, strain gauge/process input
Hide thumbs Also See for G1000 Series:
Table of Contents

Advertisement

Function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Input ON Delay
S T D CR LF
response
S T D CR LF
(Input ON Delay)
Input ON Delay
S T D
setting
S T D
Output OFF Delay
R L D CR LF
response
R L D CR LF
(Output Delay)
Output Delay
R L D
setting
Power ON Delay
P O N CR LF
response
P O N CR LF
(Power ON Delay)
Power ON Delay
P O N
setting
P O N
Back Light Time
B K L CR LF
response
B K L CR LF
(BackLight Time)
BackLight Time
B K L
setting
Contrast response
C T 1 CR LF
(Contrast)
Contrast setting
C T 1
Cross Talk response C T 2 CR LF
(Cross Talk)
Cross Talk setting
C T 2
Digital ZERO Backup
B D Z CR LF
response
B D Z CR LF
(Digital ZERO
Backup)
Digital ZERO Backup
B D Z
setting
Function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
communication
R S - CR LF
function
parameter response
R S - CR LF
(BPS,Data
Length,Parity,Stop
Bit,Delimiter)
communication
R S -
function
parameter setting
R S -
C
RS-485 address
A D R
R
setting response
(RS-485 ID)
RS-485 ID
A D R
setting response
basic function set-
S A V
value
save
・After executing "SAV COND", measurement operation is stopped, and data is saved in Flash ROM.
Transfer data
・response while ON=0.
・respond the setting contents.
・Setting range: ON=0 to 4.999(s)
O N = 0 CR LF
O N = 1 2 2 2 CR LF
・response of "RLD 0" means no this function.
・respond the setting contents.
・Setting range: 0 to 4.999(s)
4 9 9 9 CR LF
・response of "PON 0" means no this function.
・respond the setting contents.
・Setting range: 0 to 30(s)
3 0 CR LF
0 CR LF
・response of "BKL 0" means no this function,
continuously lighting.
・respond the setting contents.
・Setting range: 0 to 99(min)
5 0 CR LF
1 CR LF
・Setting range: 0 to 255
1 CR LF
・Setting range: 0 to 63
・response in case of backup.
・response in case of no backup.
・setting as ON/OFF.
O F F CR LF
transfer data
9 6 0 0 - 7 - E - 2 - C R / L F CR LF
1 9 2 0 0 - 7 - E - 2 - C R / L F CR LF
・can response and set when RS-485 is available.
LF
5 CR LF
C O N D CR LF
・Basic function setting can be changed on normal
operation,however,when power turns off,the contents of
change will disappear and return to what it was.if the
contents are not wanted to disappear even if power turns
off,execute SAV COND.
Chara
cter
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
O N = O F F CR LF
S T D
O N = 1 . 2 2 2 CR LF
S T D
CR LF
Y E S
CR LF
Y E S
O F F CR LF
R L D
4 . 9 9 9 CR LF
R L D
CR LF
Y E S
O F F CR LF
P O N
3 0 CR LF
P O N
CR LF
Y E S
CR LF
Y E S
O F F CR LF
B K L
5 0 CR LF
B K L
CR LF
Y E S
2 CR LF
C T 1
CR LF
Y E S
2 CR LF
C T 2
CR LF
Y E S
O N CR LF
B D Z
O F F CR LF
B D Z
CR LF
Y E S
Chara
cter
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 9 2 0 0 - 7 - E - 2 - C R / L F CR LF
R S -
9 6 0 0 - 7 - E - 2 - C R / L F CR LF
R S -
CR LF
・set-value is available immediately after setting.
Y E S
CR LF
・set-value is available immediately after setting.
Y E S
1 9 CR LF
A D R
CR LF
Y E S
・be not available when changes in line occupation.
be available when next line releasing or line
occupation.
CR LF
Y E S