3) Analog output
・Outputs analog voltage for monitors proportional to input of each channel.
The indicated value does not agree with the analog voltage output.
・The analog ground of sensor input and the analog ground of sensor output have the same electric
potential. (Non-isolation)
・Input and output voltage.
.
Channel (ch)
Ach
Bch
Bch
Inside of meter
Terminal No.14 AOUTA
Terminal No.15 AOUTB
Terminal No.16 AG
Load resistance : More than 10KΩ
4) Each output equivalent circuits
Inside of meter
・Photo-coupler output (NPN open collector output)
Output capacitance : voltage MAX.30V current MAX.30mA
Output saturation voltage is below 1.2V at the time of 30mA
Caution : Don't apply the inverse voltage. Use it within the output capacitance.
Input
Strain gauge sensor ±4.0mV/V
Voltage input ±0 to 10V
Current input ±0 to 20mA (4 to 20mA)
I/O control connector
(+)
(+)
External equipment B
(-)
Each output
OUT1 to OUT5
Error, SYNC
Output voltage (V)
Approx. ±6V
Approx. ±5V
Approx. ±5V
External equipment A
I/O control connector
Inductive
load (relay)
Outside power
E.COM
14/118
+