WATANABE G1000 Series Instruction Manual page 19

Graphic multi-meter, strain gauge/process input
Hide thumbs Also See for G1000 Series:
Table of Contents

Advertisement

(2) Used pattern "P00 to P15"
・All setting values can be saved up to 16 patterns of "P00 to P15".
Display the used pattern.
・The set-values of Waveform Comparison and Waveform & Displacement Comparison can be saved up
to 8 patterns of "P00 to P07".
(3) Hold key "HOLD"
・Perform ON, OFF and RESET for hold function of each sampling, Peak, valley, Peak-valley, Maximal
value, Minimal value and Inflection point.
For details, refer to「11-2 to 11-9」.
(4) Set key "MODE"
・Used when performing each data setting.
Various settings can be performed with the measurement operation stopped and each output turned
off. When the caution screen for start settings appears and "YES" is selected on it, the main setting
screen is displayed, making it possible to perform setting.
For details, refer to「5. Screen Configurations and Setting Procedures」.
(5) Display of used channel "OpA", "OpB"
・Display the analog input channel used in display of the indicated value and each output.
(6) State monitor of hold function
・"HOLD" operation state monitor: Turn red when "HOLD" key or signal STA/STB be "ON", or the
indicated value is held.
・"PEAK" operation state monitor : Turn red during detecting/holding period.
・"WAIT" operation state monitor : Turn red when "START" key or signal START waiting to be ON.
(7) Display of the indicated value and unit
(Setting of unit is performed at「7-1,3. Analog Input Setting (Ach/Bch) 」) .
(8) Display of Bar graph
・Can be displayed for each of Ach and Bch individually.
・High limit of bar graph for Ach is + SPAN indicated value and low limit is - SPAN indicated value.
・High limit of bar graph for Bch is + full scale indicated value and low limit is - full scale indicated
value.
(9) Digital Zero key "DZ"
・Set the indicated value to "0". Can be performed for each of Ach and Bch individually.
・"DZ" key can be set to "unacceptable" by「15. Basic Function Setting 2 (System)」.
・If Waveform&Displacement Comparison is selected in「6. Basic Function Setting (Setup)」, only Ach
(Y-axis) can be performed when "DZ" key is pressed.
(10) Comparison output monitors "HH", "HI", "GO", "LO", "LL"
・Show state of ON/OFF for comparison output, also show comparison set-values when in single display
screen. When in multi-display screen (2 channel), show Ach and Bch individually.
・There are also "HH", "HI", "LO", "LL" key for setting. After pressing it, 10-key input screen is shown,
and data setting is available. (Can be set during measurement operation.)
(11) Cursor key
・Switch to show or not to show the vertical line (red). When the cursor is enabled, getting waveform
can't be performed.
(12) Cursor movement key
・Can move the indicated cursor to left or right, and the crossing point "x" with the waveform can be
read out at the same time.
(13) Start key "START"
・Start or stop the getting of the analog input waveform in graph display screen, Waveform Comparison
/ Waveform & Displacement Comparison screen.
"HOLD", "PEAK", "WAIT"