2) I/O signal function
・Terminal No.1 to 5 : Comparison output (OUT1 to 5)
(Output terminal) Output signal changes by selections of each function.
Comparison output
Function
A channel
B channel
2 channel
Waveform Compare Ach
Waveform Compare Bch
Waveform & Displacement
It turns ON only when all of HI and LO of both channels are OFF.
*1
・Terminal No.6
:Error signal (Error)
(Output terminal)
・Terminal No.7
:Synchronizing signal output (SYNC)
(Output terminal)
・Terminal No.8
:Photo-coupler output common (E.COM)
(Common terminal)
・Terminal No.9
:Start / Peak hold Ach (STA)
(Input terminal)
・Terminal No.10
(Input terminal)
:Digital Zero Ach (DZA)
・TerminalNo.11
(Input terminal)
・Terminal No.12 :Digital Zero Bch (DZB)
(Input terminal)
・Terminal No.13 :Digital ground (DG), is connected with terminal No.25 (DG) inside.
(Common terminal)
OUT1
(No.1)
HI (Ach) LO (Ach)
HI (Ach) LO (Ach) GO (Ach)
―――
HI (Ach) LO (Ach) GO (Ach) HI (Bch) LO (Bch)
comparison
In Waveform & Displacement Comparison, when displacement (indicated value)
changes suddenly, or displacement (indicated value) has not been updated for
some time, turn the ERROR signal ON.
For details, refer to「12-3. Waveform & Displacement Comparison」.
Be ON when the indicated value and comparison result have been finalized.
Please use it when reading the output signal.(Details according to each timing
chart)
The common output terminal of terminal No.1 to 7 (OUT1 to 5, Error, SYNC).
For details, refer to「3-4. 4) Each output equivalent circuits」
Control terminal of Start / Peak hold action of Ach. (ON ("0") trailing edge is
active)
For details, refer to「11. Hold Function (Hold)」.
:Start / Peak hold Bch (STB)
Control terminal of Start / Peak hold action of Bch. (ON ("0") trailing edge is
active)
For details, refer to「11. Hold Function (Hold)」.
The terminal of turning the indicated value to 0 for Ach. (ON ("0") trailing edge
is active)
For details, refer to「4-6. Functional Description (9)」and「12-3. Waveform &
Displacement Comparison」.
The terminal of turning the indicated value to 0 for Bch. (ON ("0") trailing edge
is active)
However, if Waveform & Displacement Comparison is chosen by meter setup in
the basic function setting, it is denied.
For details, refer to「4-6. Functional Description (9)」and「12-3. Waveform &
Displacement Comparison」.
The common input terminal of terminal No.9 to 12 (STA, STB, DZA, DZB).
For details, refer to「3-4. 6) Each input equivalent circuits」.)
OUT2
OUT3
(No.2)
(No.3)
HH
HI
HH
HI
GO (*1)
GO (Bch) HI (Bch) LO (Bch)
―――
OUT4
OUT5
(No.4)
(No.5)
GO
LO
GO
LO
HI (Bch) LO (Bch)
―――
―――
12/118
LL
LL