11
Figure 2-3. Daily Walk-Around Inspection
(Sheet 2 of 2)
3121296
10
9
8
7
6
LIFTPOD by JLG
SECTION 2 - PREPARATION AND INSPECTION
bottom of mast pin mount when released, see Figure
2-4.
6. Adjustable Leveling Feet/Locking Castor Wheel -
Check for any debris stuck to or around mechanism.
Check for damage. FT70-Non-skid pads (on bottom of
foot) must be in good working order. FT140 - Castor
wheel swivels freely and wheel brake working prop-
erly.
7. Swivel Castor Mechanism (FT70) - Engage handle is
not bent or broken. Check for any debris stuck to or
around mechanism. Castor wheel swivels freely.
8. Manual Descent Crank - Ensure it is present and
securely attached in platform (See Figure 2-5.).
9. Platform Assembly and Gate - Check mounting pins
are not loose; platform railing is undamaged; self-clos-
ing entry gates are in proper working order; no cracks
or corrosion visible.
10. Tool Tray - See "Tool Tray Pre-Start Inspection" on
page 2-7.
11. Powerpack - Control and Drive Unit (FT70 - Control
Unit optional) - Ensure it is properly mounted and
latched onto mast cap. Button, triggers and switches
not obscured or damaged; decals secure and legible;
emergency stop switch reset for operation; control
markings legible. Battery is installed and secure.