SECTION 7 - TROUBLESHOOTING
TROUBLE
Machine does not assemble properly
Improper alignment on assembly
Platform not fully engaged
Powerpack (optional) motor does not start
Emergency stop button is engaged (PUSHED IN) on
powerpack
Direction selector or enable button not activated
Battery not installed or no charge
Motor has overheated
Platform does not lift up from bottom of travel - motor starts
Driveshaft interlock is engaged
(If using powerpack) Powerpack driveshaft not
engaged
Emergency stop button is engaged (PUSHED IN) on
powerpack
7-2
Table 7-1. Troubleshooting
PROBABLE CAUSE
Check each component and assembly alignment is correct.
Check alignment and slide parts on until platform latch is properly engaged.
Disengage emergency stop button until it pops up (TURN CLOCKWISE).
Press and hold the enable button, then press and hold the 'UP' button continuously for opera-
tion, release when desired height is reached.
Properly install charged battery in powerpack.
Wait until motor cools. The temperature cutout resets itself automatically.
Alternatively use manual descent procedure to lower platform (Section 4.1).
Push cordless drill on driveshaft down firmly to disengage driveshaft safety interlock.
Check powerpack is correctly fitted to platform, latch is down and drive shaft is connected to
drive shaft.
Disengage emergency stop button until it pops up (TURN CLOCKWISE).
LIFTPOD by JLG
REMEDY