Battery Operation

DO NOT SHORT CIRCUIT THE BATTERY. DO NOT OPEN THE BATTERY PACK AS
THERE IS A DANGER OF CAUSING A SHORT CIRCUIT.
PROTECT THE BATTERY AGAINST HEAT, INCLUDING AGAINST CONTINUOUS
DIRECT SUN EXPOSURE OR OPEN FLAME.
New batteries and batteries that have not been used for a long
period must be fully charged. They will not reach their full
capacity until fully charged and discharged through several
cycles. Battery performance will be limited at low temperatures.
The battery can be charged and discharged hundreds of times
but will eventually wear out and need to be replaced. A signifi-
cantly reduced operating period after charging indicates that
the battery must be replaced.
NOTICE
CHECK THE REMAINING CHARGE INSIDE THE POWERPACK'S BATTERY
BEFORE ELEVATING THE PLATFORM BY PRESSING THE CHARGE STATUS INDI-
CATOR BUTTON ON THE BATTERY. IF ONLY ONE LED COMES ON, EITHER
CHARGE THE BATTERY, OR REPLACE WITH FULLY CHARGED BATTERY.
3121296
Removing Battery From Power Pack Control Unit
Figure 3-21. Battery Removal - Powerpack Control Unit
1. Power Pack Control Unit lying face
down
2. Battery Pack
LIFTPOD by JLG
SECTION 3 - MACHINE OPERATION
1
2
3
3. Battery Cover opened out of the
way.
4. Battery Release Latch (Press to
Remove Battery)
4