User Sets (Memory Channels); Genicam User Set Control - FLIR GRASSHOPPER 3 Series Technical Reference

Gige vision
Table of Contents

Advertisement

5.2

User Sets (Memory Channels)

The camera can save and restore settings and imaging parameters via on- board user configuration sets, also
known as memory channels. This is useful for saving default power- up settings, such as gain, shutter, video
format and frame rate, and others that are different from the factory defaults.
User Set 0 (or Memory channel 0) stores the factory default settings that can always be restored. Two additional
user sets are provided for custom default settings. The camera initializes itself at power-up, or when explicitly
reinitialized, using the contents of the last saved user set. Attempting to save user settings to the (read- only)
factory default user set causes the camera to switch back to using the factory defaults during initialization.
The following camera settings are saved in user sets.
Acquisition Frame Rate and Current Frame Rate
n
Image Data Format, Position, and Size
n
Image mirror, if applicable
n
Current Video Mode and Current Video Format
n
Camera power
n
Frame information
n
Trigger Mode and Trigger Delay
n
Imaging Parameters such as: Brightness, Auto Exposure, Shutter, Gain, White Balance, Sharpness, Hue,
n
Saturation, and Gamma
Input/output controls such as: GPIO pin modes, GPIO strobe modes, GPIO PWM modes
n
Color Coding ID/Pixel Coding
n
Packet Size, Packet Delay, GVCP Configuration, and Heartbeat
n
To access user sets:
GenICam—User Set Control
n
5.2.1

GenICam User Set Control

Name
CurrentUserSet
UserSetSelector
UserSetLoad
UserSetSave
DefaultUserSet
2/10/2017
©2013-2017
FLIR Integrated Imaging
Solutions Inc. All rights reserved.
Display
Name
Indicates the user set that is currently in use. At initialization
Current User Set
time, the camera loads the most recently saved user set
User Set
Selects the user set to load or save
Selector
Loads the user set specified by the User Set Selector to the
User Set Load
device and makes it active
Saves the user set specified by the User Set Selector to the
User Set Save
non-volatile memory of the device
Default User Set
Selects the default user set as the default start up set
®
Grasshopper
5 General Grasshopper3 PGE Operation
Description
3 PGE Technical Reference
Value
0 (default)
1
2
Default
User Set 1
User Set 2
Write Only
Write Only
Default
User Set 1
User Set 2
29

Hide quick links:

Advertisement

Table of Contents
loading