Repacking the System Components
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
Caution
Be sure to push the chassis only on its frame. Do not push on any of its modules or use the handles on
any modules—these handles are used only for removing or installing these modules. Do not use the
handles on the side of the chassis to move or lift the chassis (the handles are not rated for lifting over
200 pounds [91 kg]). The chassis handles are only for adjusting the position of the chassis in the rack or
cabinet.
After you securely position the chassis on the mechanical lift, use the mechanical lift to move the chassis
Step 13
to its pallet.
Step 14
Lower the chassis to the level of the pallet or no more than 0.25 inches (0.6 cm) above the pallet.
Caution
You need four persons for the following step.
Use at least four persons to push the chassis onto the raised portion of the pallet. Position the chassis so
Step 15
that it is 4 inches (10.2 cm) away from the side of the common edge of the pallet and its raised portion.
Attach two angle brackets to the raised portion of the pallet between the chassis and the pallet edge. Do
Step 16
not tighten the screws that hold these brackets to the pallet—you will need to adjust their placement after
you place the chassis on the pallet. See
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
E-8
Appendix E
Repacking the Cisco Nexus 7000 Series Switch for Shipment
Figure
E-2.
OL-23069-06