Chapter 9
Replacement Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
1
Put the module in an ESD bag.
2
Place the bagged module on the foam pad.
3
Attach a side pad to each of the long sides of
the module.
4
Fold the side flaps up along the side pads.
5
Fold the long flaps up along the ends of the
module and then over the top of the module.
Insert the two tabs on each flap into the side
flaps.
6
Insert the folded box into the slightly larger
box.
On the replacement module, rotate both of the ejector levers away from the front of the module.
Step 12
If you are inserting the module into a Cisco Nexus 7010 chassis, rotate the module 90 degrees clockwise.
Step 13
Align the module to the chassis guides for the vacated slot (slot 5 or 6 on the Cisco Nexus 7010 chassis
Step 14
or slot 9 or 10 on the Cisco Nexus 7018 chassis), and slide the module part way into the slot.
With one or both hands on the front of the module, push the module all the way into the slot until it seats
Step 15
on the midplane connector.
Simultaneously push both ejector levers inward until they come in contact with the face of the module.
Step 16
The module should be fully seated in the slot and the captive screws should be aligned with their holes
in the chassis. The EMI gasket should close the gap between the new module and the module in the next
slot to the right.
Screw in the two captive screws to the chassis and tighten them to 8 in-lb (0.9 N·m).
Step 17
Reconnect the console cable to the CONSOLE SERIAL PORT as explained in the
Step 18
Console" section on page
If the previous supervisor module was connected to an asynchronous device through a modem, connect
Step 19
the modem cable to the COM1/AUX SERIAL PORT as explained in the
section on page
Step 20
Reconnect the network management cable to the MGMT ETH port as explained in
Management Interface" section on page
Step 21
Reconnect the CMP cable to the CMP MGMT ETH port as explained in
CMP Port" section on page
Verify that both supervisors have the same amount of memory by following these steps:
Step 22
a.
Use the show system resources command to see how much memory is installed in the active
supervisor.
Use the system switchover command to make the other supervisor module active.
b.
Use the show system resources command to see how much memory is installed in the other
c.
supervisor.
OL-23069-06
6-2.
6-2.
6-4.
6-5.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
Replacing a Supervisor Module
7
Tape the flap to the box.
8
Insert the two box sides into foam blocks.
9
Place the box and its foam blocks into the
larger box.
10 Fold the narrow flaps over the smaller box and
foam blocks.
11 Fold the wide flaps over the box.
12 Tape the wide flaps together and to the box.
"Connecting to the Console"
"Connecting the Supervisor
"Connecting to the
"Setting Up the
9-17