Replacing A Supervisor Module In A Single-Supervisor System - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Replacing a Supervisor Module
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
If one of the supervisor modules has more memory than the other supervisor module, you must either
remove 4 GB from the module with 8 GB (see the
Module" section on page
to a Supervisor Module" section on page

Replacing a Supervisor Module in a Single-Supervisor System

If you need to replace the supervisor in a single-supervisor Cisco Nexus 7000 Series system, you must
shut down the system before replacing the supervisor.
A replacement supervisor module comes with one DIMM (4 GB of memory) or, if your switch is running
Note
Cisco NX-OS 5.1 (or later release), two DIMMs (8 GB of memory). If the switch not running a version
of Cisco NX-OS that is compatible with using 8 GB of memory, you must use only one DIMM (do not
install an additional DIMM).
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
Warning
when servicing. Statement 1034
Handle the supervisor module carefully using an ESD wrist strap, holding the module only on its carrier
Caution
edges without touching any electronic circuitry, and placing the module on antistatic mats or antistatic
foam when it is not installed in the Cisco Nexus 7000 Series chassis.
To replace a supervisor module in a single-supervisor system, follow these steps:
Place an antistatic mat or antistatic foam where you can place the new and old supervisor modules.
Step 1
If the replacement supervisor is in a shipping box, prepare the module for installation by following these
Step 2
steps:
a.
b.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
9-18
9-23) or add 4 GB to the module with 4 GB (see
Open the shipping box for the module and remove the module from its antistatic wrapping.
If the plastic protector shown in
the back of the module. Keep the plastic protector and the other packing materials so that you can
easily ship the module at a later time.
"Removing 4 GB of Memory from a Supervisor
9-21).
Figure 9-7
is included with the module, remove it by pulling it past
Chapter 9
Replacement Procedures
the"Adding 4 GB of Memory
OL-23069-06