Manage Temperature Settings

Button
Setpoints
Define the setpoint temperatures for heated
(internal and external) zones.
Touch
for all connected zones
Touch
individually.
NOTE: To minimize charring the adhesive
material, you can define the hopper setpoint
temperature up to 15C (30F) cooler than the
reservoir setpoint temperature
NOTE: The Hopper setpoint temperature
cannot exceed that of the reservoir.
Temperature
Temperature Limits
Limits
Define the over and under temperature
threshold values, allowing the system to
alert you before an over/under temperature
fault occurs.
NOTE: For setpoint limits, the system uses
the differential temperature conversion
method. For Celsius to Fahrenheit multiply
Celsius by 1.8. For Fahrenheit to Celsius
divide by 1.8
PID Settings
Define the Proportional, Integral and
Differential (control aspects) of standard or
large applicators, hoses and air heaters.
Heater Zone
Enable or Disable individual external zones.
Control
Ready Delay
Define the amount of time to delay the
Melter "Ready" (green) status, thereby
allowing enough time for the hot melt
material in the reservoir to reach its normal
operation.
E 2011 Nordson Corporation
Configuring and Modifying Temperature, Pump and Melter Settings
The following table details each temperature settings.
Use this to...
to define one global temperature
(the default) to define each zone
Default
Internal Zones:
Min: 40C (100F)
Temp: 175C
Max: 230C
(350F)
(450F)
External Zones:
Temp: 175C
(350F)
Over Temp Limit:
Over Temp
15C (25F)
Limit:
Min: 5C (10F)
Max: 60C
(110F)
Under Temp Limit:
Under Temp
25C (50F)
Limit:
5C (10F)
60C (110F)
Zone A – Hose
Hose Standard
Zone B – Standard
Applicator
Applicator
Large
Applicator Air
heater
Internal : Enabled
Enabled
External: Disabled
Disabled
NOTE: If you
defined a Global
temperature, then
all external zones
with connected
devices
automatically
become Enabled.
0 minutes
Min: 0 minutes
(disabled)
Max: 1440
minutes
6-3
Range
Part 1120130