6-4
Configuring and Modifying Temperature, Pump and Melter Settings
Manage Pump Settings
Button
Pump Speed
Manually finetune the pump RPM in either
Manual or GeartoLine mode.
Operation Mode
Decide which pump operation mode,
GeartoLine or Manual you want to use.
S
Use GeartoLine to deliver adhesive
output at a rate proportional to the speed of
the production line.
NOTE: A linespeed input must be provided if
you want to use the geartoline capability.
S
Use manual to:
Auto Pump
Make better use of your time by allowing you to
touch the Master Pump Control button while
the melter status indicates Heating (yellow)
and walk away to perform other tasks.
When the melter status indicates Ready
(green) the pumps automatically start.
NOTE: The Master Pump Control button
changes color to light blue if the Auto Pump
On option is enabled and...
Remote Control
Enable or Disable a pump from a location
other than the melter console.
Part 1120130
The following table details each temperature settings.
Use this to....
S
Clean or purge the pump.
S
Deliver adhesive output at a continuous
rate.
S
You touch the Master Pump button
while melter is in the process of heating
the zones to their setpoint
temperatures.
S
You take the melter out of Standby
Mode, and you touch the Master
Pump button.
Default
(Recommended)
Min: 0 (factory)
Min: 18 RPM
Max: 94 RPM
Max: 80 RPM
(Factory)
Manual
Manual
GeartoLine
Disabled
Disabled
Enabled
Disabled
Disabled
Enabled
E 2011 Nordson Corporation
Range