7-6
Service

Motor and Gear Box

Changing the Motor Lubricant

Part 1120130
Remove the gear motor assembly from the melter.
S
Use only the stated lubricant or one that has proven to be equivalent
(refer to Lubricant Selection). Using any other lubricant can result in
premature wear and/or damage to the gear box.
S
Drain lubricant when warm.
S
Properly dispose of the old lubricant according to local regulations.
CAUTION! Never mix different types of lubricants.

Lubricant Changing Interval

Operating temperature < 100 _C / 212 _F:
Every 15000 hours of operation or at least every 4 years.

Lubricant Capacity

Ensure that the upper gears and rolling bearings are properly lubricated.

Lubricant Selection

Lubricant manufacturer
AGIP
ARAL
BP
DEA
ESSO
KLÜBER
OPTIMOL
SHELL
TEXACO
Mineral oil CLP 220
Blasia 220
Degol BMB 220 or Degol BG 220
Energol GR-XP 220
Falcon CLP 220
Spartan EP 220 or GP 90
Klüberoil GEM 1-220
Optigear 220
Omala Oil 220
Geartex EP-A SAE 85 W-90
E 2011 Nordson Corporation