Troubleshooting

Touch Screen Alerts and Faults

About Touch Screen Messages

Screen Message
Affect on Melter
Internal or External
Temperature for
[ZoneName] has
dropped below
Alert condition - an
defined setpoint
issue has been
threshold
detected. The
melter continues to
Internal or External
operate normally.
Fault condition - if
Temperature for
the issue is not
[ZoneName] has
resolved within 2
risen above defined
minutes of the alert
setpoint threshold
message, the
Internal or External
master pump and
heaters are switched
Short RTD on
off. Melter stops
[ZoneName]
functioning
Internal or External
Open RTD on
[ZoneName]
The melter may not
Issue with a pump
continue to work.
Part 1120130
The Nordson AltaBlue Touch Adhesive melter diagnoses many alert and
fault conditions that may occur during operation. An "alert" condition is a
situation in which a potential problem may be occurring with the melter,
pump, applicator or hose. The melter will operate under an "alert" condition
unless the problem goes unresolved, at which point the melter will go into a
"fault" condition, during which the melter will shut down until the problem is
resolved.
Refer to the appropriate table for more information.

Pump and Zone Alerts/Faults

Table 8-1 Pump and Zone Alerts/Faults
Cause
The actual temperature of the
component has dropped below
the set temperature limit
The actual temperature of the
component has risen above the
set temperature limit
The RTD for the component
indicated has failed or the
component was disconnected
from the melter.
Refer to "Troubleshooting Pumps" later in this section for more
information
Corrective Action(s)
Check for conditions that may
cause a drop in ambient
temperature or replace the
component.
Check for conditions that may
cause an increase in ambient
temperature or replace the
component.
Check the connections, or
replace the RTD
E 2011 Nordson Corporation