Cleaning the Tank

Draining Material from the Tank

Cleaning the Tank by Hand

Tightening the Fixing Screws

Connection
Tank/reservoir
Manifold/reservoir (high melt)
E 2011 Nordson Corporation
Pump material out of the melter.
CAUTION! Do not feed charred material though the applicator. Particles can
block the applicator. Instead unscrew hose (refer to Section 3, Installation).
Cold material can usually be peeled off of the sides of the tank. If necessary,
first heat tank to material softening temperature, usually approximately
70 ° C / 158 ° F.
NOTE: The inside of the tank is release coated. Do not use metallic tools to
clean. Do not use wire brushes! This could damage the release coating.
Heating and cooling that occurs during daily operation can cause the fixing
screws to loosen. Tighten screws as indicated in the table below.
NOTE: Tighten fixing screws only using a torque wrench and when the
melter is cold.
Thread
M 6
M 8
Service
Torque
6−8 NSm / 53−71 in.-lb
5−7 NSm / 44−62 in.-lb
Part 1120130