5.4.1.4 Maximum Duration
This setting is displayed if mode:
Automatic Pool Refill always refills approximately the same volume of water, which
corresponds to approximately 2cm of water at the pool surface. Therefore, as the
water supply usually delivers a constant rate the expected refill duration can be
estimated. Use the
MAX DURATION
volume) added to the pool during a refill operation. This protects against excessive
water consumption in case of significant pool leaks.
The
MAX DURATION
is a daily timeout for pool refill. If reaching the maximum
duration during a 24 hour period, refill stops until the following day and an alert is
sent advising of this condition. Check for possible leaks or low water supply pressure.
The Alert is reset at midnight and another refill can be commanded the following day.
If this situation occurs on 3 consecutive days, Water topup will be postponed until
the alert is cleared manually
5.4.1.5 Draining
This setting is displayed if mode: REDUCE, AUTO.
Set the duration for the water reduction cycle;
If the level is detected V_HIGH, then PoolCop will reduce water level following this
logic:
Water will preferably be consumed for backwashing the filter (if permitted,
see 5.6.3 Filter Data), otherwise it will be sent to waste.
With "classic" pools, reduction will be launched if level sustains
15 minutes.
With rimflow pools, pump will be started immediately when level is detected
V_HIGH
and will run until either:
level returns
o
Level stays
o
reduce cycle and then the pump will stop.
Level stays
o
reduce cycle and then the pump will stop.
Up to three cycles will be carried out per day.
www.poolcop.com
REFILL
or AUTO.
parameter to limit the time (and hence water
NORMAL
V_HIGH
for 15 minutes, which will launch a water level
HIGH
for 3 hours, which will also launch a water level
Technical Support "Hotline" +33 (0)4 90 09 54 26
Default:
Entries:
Default:
Entries:
V_HIGH
for
P a g e | 7 5
60min
10-720min
120 seconds
10–600 seconds