P a g e | 3 2
D
I S I N F E C T I O N
PoolCop is compatible with all types of water disinfection. Disinfection can be with or without chemicals.
3.5.4.1 Timer Control and Programming
3.5.4.1.1
Information and Guidance
PoolCop auxiliary relays can be used for timed dosing of chemicals such as chlorine, bromine, active oxygen, PHMB, etc. or for the
timed control of external water treatment systems
External equipment or an ON/OFF dosing pump (peristaltic or electromagnetic) with installation kit is required.
Always follow all the chemical manufacturer's instructions and guidelines for correct usage, handling and
3.5.4.1.2
Installation
Install the equipment or dosing pump, associated suction and injection pipes and connectors as per the manufacturer
supplied installation manual.
Ensure that the correct consumable is installed and secured.
Route the power supply for the equipment via the chosen auxiliary relay or relays in the PSU.
Connect the equipment to the mains power supply as per the manufacturer's installation manual, ensuring adequate
electrical protection and conformity.
Testing and priming a dosing pump, if applicable:
In
MANUAL CONTROL
o
If needed carry out the necessary pump priming sequence according to the dosing pump instruction and
o
installation manual.
3.5.4.1.3
Timer Programming
Calculate an appropriate dosing time.
Refer to the instruction manual and pump rate, and the instructions for use of the chemical to be injected.
Generally the larger the pool the higher this set time will be. The volume dosing is calculated as follows:
Dosing Time x Pump Size = Total Dosing Volume
Example: Dose time 3 min, Pump Size 25 ml/min therefore 3 min x 25 ml = 75 ml in 3 minutes.
In the
AUXILIARIES MODES
programmed filtration cycle.
In the
AUXILIARIES MODES
In the
AUXILIARIES MODES
Ensure that this time programmed is during a filtration cycle so that the dosing is carried out at a time that
www.poolcop.com
Always wear correct chemical resistant hand protection when handling chemicals.
Always wear correct eye protection when handling chemicals.
Peform regular water analysis to ensure correct and safe chemical levels.
menu, select the respective AUX to ON; the equipment or pump must run.
menu, set the timer for the appropriate auxiliary to run for the calculated dosing time during a
menu, set SLAVE: YES.
menu, select days of the week on which dosing is to take place.
Technical Support "Hotline" +33 (0)4 90 09 54 26
WEAR HAND PROTECTION:
EYE PROTECTION:
WARNING:
dosing.
WARNING:
WARNING:
the filtration system is running.
P o o l C o p M a n u a l : V 3 1 E N
PCFR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PoolCop and is the answer not in the manual?

Questions and answers

Related Products for PoolCop PoolCop

This manual is also suitable for:

Poolcop junior

Table of Contents