PoolCop Installer And User Manual page 62

Table of Contents

Advertisement

P a g e | 6 2
4.4.4.4 Understanding Pump Modes
On the PoolCop main display, next to Pump you will see the
mode in which the pump and filtration are running, or OFF.
The mode that has started and/or is now causing the pump to
be on will be displayed. In this example, the pump is filtering in
AUTO (see below) and a pressure of 0.98 Bar is displayed.
Valve
Mode
What's happening now?
Positions
The filtration pump is OFF. No filtration
STOP
All
cycles are defined.
The pump was started by the user, or by
the external run pump command, and is
running outside a programmed timer
MAN
All
period
Or
Pump is running inside a filtration cycle
but valve is not in filter position.
Filtration was started by or has now
entered a Filtration Timer cycle using
TIMER
Filter
user programmed timer settings in Cycle
1 and/or Cycle 2 in TIMER mode.
Filtration was started by or has now
entered the Filtration Timer cycle and is
AUTO
Filter
in an automatic mode (either ECO+ or
VOLUME).
Filtration is in Mode Forced, which was
FORCE
Filter
selected
Operations.
PoolCop is detecting a freezing risk and
is running the filtration to use warmer
FRZ
Filter
water from the pool to reduce the risk of
the pool or equipment freeing.
Filtration
because a filtration cycle ends or a
PAUSE
All
manual command or an event stopped
the pump.
Filtration has been started because of an
external request. (An input is configured
EXT
Filter
to fulfil this behaviour) or Very High level
has been detected in the pool.
www.poolcop.com
I always take care of your pool in the most intelligent manner
possible, controlling the pump and filter to give you the greatest
Fundamental to understanding what is happening is for you to know
why the pump is running at this moment, and for that you simply
check which MODE is currently active.
by
the
user
in
is
momentarily
stopped
Technical Support "Hotline" +33 (0)4 90 09 54 26
benefit possible.
1 2 : 4 6 : 0 1
Valve
Pump AUTO
Water Temp
AirTemp
Level
pH/ORP
M E N U
Water
What will happen next?
Treatment
The filtration will remain OFF as long as there is
OFF
no filtration cycle or no manual command to
start the pump.
PoolCop will revert to the programmed filtration
OFF
cycles (including repositioning the valve to Filter)
when the next timer starts.*
PoolCop will use fixed programmed timer
Active
settings to start and stop the filtration.*
PoolCop is optimising the filtration duration
Active
based on measured temperature, as well as pool
and pump data settings.
Filtration will run for 23:00 per day for the
duration selected (24, 48 or 72 hours). PoolCop
Manual
Active
will then revert to the programmed filtration
cycles (including repositioning the valve to Filter)
when the next timer starts.*
30min after freezing risk has cleared, PoolCop
Active
will revert to the programmed filtration cycles
when the next timer starts.*
Filtration will automatically restart with the next
OFF
filtration cycle.
Filtration will be running as long the external
OFF
request is present, although it will respect the 2 x
1/2h pause per day.
P o o l C o p M a n u a l : V 3 1 E N
0 1 / 0 6 / 2 0 1 4
: Filter
: 0.98
: 28
: 32
: Normal
: 7.2/690
Bar
°C
°C
PCFR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PoolCop and is the answer not in the manual?

Questions and answers

Related Products for PoolCop PoolCop

This manual is also suitable for:

Poolcop junior

Table of Contents