PoolCop Installer And User Manual page 64

Table of Contents

Advertisement

P a g e | 6 4
4.4.4.5.7
Forced Filtration: 24h, 48h or 72h
PoolCop normally runs on timers and on automatic modes, adjusting the filtration duration as required. When required however,
forced running of the pump in Filter can be selected. This allows a fixed length filtration duration which is useful under certain
conditions.
FORCED
mode changes Filtration Timer Cycle 1 times. When the forced duration is completed, previous settings for Cycle 1 are
restored. This mode does not affect Cycle 2 settings.
FORCED
mode is only available for the valve position Filter; activating the mode will reposition the valve to Filter.
In
FORCED
mode, the maximum daily duration is limited to 23:00; with either one or two stopped periods to allow for PoolCop
measurement functions and daily self-test to occur. Normal automatic filter cleaning may occur during
treatment is active during this mode.
The time remaining in Forced mode is displayed in whole hours on the pump Manual Control screen and on Filtration Mode screen.
Any active forced filtration mode is deactivated when the duration has expired, and the Filtration Timer cycles will resume normal
control as programmed.
Forced mode can be stopped either by stopping the pump manually either by changing the filtration mode.
Pump stop
Navigate to
PUMP
The pump will be ON, and pressure will be displayed.
Press
SELECT (PUMP
Press
SELECT (PUMP: OFF
Press SELECT. The pump will stop, and pressure will
reduce.
Mode change
Navigate to
MODE
The mode will be FORCE, remaining time (18 Hours
here) and the return mode
displayed.
Press
SELECT (MODE
Use the ARROWS to change mode.
Press
SELECT
to validate the new mode.
www.poolcop.com
in the
MANUAL CONTROL
is preselected).
will display).
in the
FILTRATION MODES
(ECO+
here) will be
is selected).
Forced mode is not cancelled during automatic or user launched filter cleaning cycles.
Technical Support "Hotline" +33 (0)4 90 09 54 26
S I N G L E S P E E D P U M P
>
Pump
menu.
Speed
Valve
Pressure
S E L E C T
> Mode
menu.
Cycle 1 ON
Cycle 2 ON
S E L E C T
NOTE:
P o o l C o p M a n u a l : V 3 1 E N
FORCED
:
ON
:
---
:
Filter
:
0.98
Q U I T
F I L T R A T I O N
:
FORCE18H
:
08:05
0
:
OFF
14:18
2
0
:
14:48
:
6
1
OFF
:
07:35
3
:
2
1
ECO+
0
4
:
8
Q U I T
5
0
:
0
4
3
X
mode. Water
Bar
X
X
X
X
PCFR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PoolCop and is the answer not in the manual?

Questions and answers

Related Products for PoolCop PoolCop

This manual is also suitable for:

Poolcop junior

Table of Contents