Filtration Mode Menu; Mode - PoolCop Installer And User Manual

Table of Contents

Advertisement

P a g e | 7 2
5.2

Filtration Mode Menu

Set the duration and times for
daily filtration.
The filtration timer has two cycles in any 24 hour period, Cycle 1 and Cycle 2; these cycles are pre-set or are available for any setting
depending on the filtration mode selected.
It is recommended to keep at least 2x30min of free time (no filtration) per day. This will permit pH
M
O D E
Filtration timer has 8 modes of operation
In
STOP
mode, filtration timers are set to 00:00. The filtration will never run in
automatic mode.
In
TIMER
mode, filtration Cycle 1 and Cycle 2 times are set by the user.
In
ECO+
mode, PoolCop adjusts filtration duration based on measured water
temperature, filtration rates, and other factors. This mode allows PoolCop to
automatically adjust the filtration duration based on changing seasonal and
weather conditions and thus protect water when temperature is high and save
energy if temperature is low.
Set Cycle 1 as desired. Duration will be taken into account when
o
calculating Cycle 2 duration.
Set the Cycle 2 Filtration ON time. PoolCop calculates and sets the OFF
o
time, with X indicated.
The duration is automatically calculated based on the average measured
o
temperatures during filtration in the last 24 hour period.
Other pool data settings, including pool volume and rate, are used to
o
correct calculated duration to ensure that adequate filtration is carried
out daily.
VOLUME
mode is based on the same model as
difference:
In
ECO+
Mode, the filtration duration is calculated is made using the
o
pool temperature.
VOLUME
Mode does not take temperature into account, but simply use
o
the turnover rate defined in the Pool data menu to estimate the
filtration time.
In
CONTINUOUS
time so that the global filtration is 23/24. The only available setting is the
starting time of Cycle1.
In
FORCE
mode (24H, 48H or 72H) filtration will run 23/24 for the selected
period and the will revert back to normal setting. Forced mode is achieved by
temporarily setting Cycle 1 timer value so that, added to Cycle 2, the filtration
duration is 23 hours. No timer settings are available in Forced mode.
ECO+ Mode uses the daily average water temperature to calculate filtration duration. After a Factory Reset
the default filter time is approximately 8 hours, based on an assumed temperature of 20°C.
www.poolcop.com

Mode

Cycle 1 ON
Cycle 2 ON
S E L E C T
measurement, periodic filter cleaning, and automatic pool refill if installed.
mode, Cycle1 and Cycle 2 have the same 11:30 duration
An updated calculation is performed automatically at 17:00.
Technical Support "Hotline" +33 (0)4 90 09 54 26
F I L T R A T I O N
: ECO+
: 02:30
OFF
: 06:45
: 12:00
OFF
: 18:43 X
:
Q U I T
NOTE:
ECO+
Mode with a noticeable
NOTE:
P o o l C o p M a n u a l : V 3 1 E N
Default:
STOP
Modes:
STOP;
TIMER;
ECO+;
VOLUME;
CONTINUOUS;
FORCE24H;
FORCE48H;
FORCE72H
PCFR