Sto Connectors; Mains Connectors - Danfoss VLT ISD 510 Design Manual

Integrated servo drive
Hide thumbs Also See for VLT ISD 510:
Table of Contents

Advertisement

Specifications

6.2.3.1 STO Connectors

Item Position
on SAB
STO
Front
1 IN:
STO
STO
Front
2 IN:
STO
6
6
STO
Front
1 IN:
24 V
STO
Front
2 IN:
24 V
ISD
Underside Used for STO
Line
1:
STO
1
ISD
Underside Used for STO
Line
2:
STO
2
Table 6.14 STO Connectors
70
VLT
Description
Drawing/
Ratings
pins
Used for STO
Nominal voltage:
24 V DC ±10%
input voltage
1.
Nominal current:
+ STO –
Depends on the
Used for STO
Pins (left
number of servo
input voltage
to right):
drives in the
2.
STO+
application.
STO-
Maximum current:
1 A
Maximum cross-
section:
1.5 mm
These
Nominal voltage:
24 V DC ±10%
connectors can
only be used
Nominal current:
+ 24V –
to make a
1 A
Pins (left
bridge to STO
Maximum cross-
to right):
1 IN: STO and
section:
24+
STO 2 IN: STO
1.5 mm
24-
if the STO
function is not
required in the
application.
This connector
cannot be
used for any
other function.
Nominal voltage:
+ STO –
24 V DC ±10%
output voltage
1.
Nominal current:
Pins (left
Depends on the
to right):
number of servo
STO+
drives in the
STO-
application.
output voltage
Maximum current:
2.
1 A
Maximum cross-
section:
0.5 mm
Danfoss A/S © 08/2017 All rights reserved.
®
®
Integrated Servo Drive ISD

6.2.3.2 Mains Connectors

Item
AC mains
supply
Mains PE
(terminal
2
95)
Table 6.15 Mains Connectors
2
1
1
PE screw (terminal 95)
Illustration 6.31 PE Screw
2
510 System
Description
Drawing/
pins
Used to connect
L1/L2/L3
L1
L2
L3
Pins (left to
right):
L1
L2
L3
The PE screw is used
to connect the
protective earth, see
Illustration 6.31.
Ratings
Nominal
voltage:
400–480 V AC
Nominal
current:
12.5 A
Maximum
cross-section:
4 mm
2
Minimum
cross-section:
2
10 mm
MG36C102