USC U-Batch Operator's Manual page 56

Treater
Table of Contents

Advertisement

Remove drive belt guards and check for any play in the drive motor or reducer
shafts.
Check the drive belt tension. Adjust if necessary (see page 58).
Grease the upper and lower auger shaft bearings every 40 hours of operation.
The reducer is filled with synthetic lubricant and requires no periodic maintenance.
However, an occasional visual inspection to check for hardware tightness, leakage
and the general overall condition of the reducer is good practice.
Run clean water through the static mixer assembly and purge with compressed air
regularly to avoid chemical build-up.
Clean the entire hopper, including the slide gate assembly with clean water
regularly to avoid chemical build-up.
Grease the upper and lower auger shaft bearings every 40 hours of operation.
 Check and tighten wire connections.
 Check quick connects on bottom of control panel.
 Check to see if starters and/or overloads are tripped.
 Check to see if relays, timers and/or breakers are tripped.
 Check quick connects on end of Auxiliary cord.
 Check and tighten wire connections.
 Check relay and fuse holder.
 Check power cords for cuts or frays and ensure ground is present.