USC U-Batch Operator's Manual page 29

Treater
Table of Contents

Advertisement

U-BATCH™ TREATER
MAIN SCREEN
17B. PAUSE BLEND:
Pressing this button and holding it for two seconds will
terminate the blending run.
18. START SETUP:
Pressing this button brings up the Blend Setup popup screen.
A
B
C
D
18A. EXIT:
This button is used to close the popup screen. It Is functionality the same
throughout the HMI display.
18B. AUTO ALL DEVICES:
When this button is pushed, it globally changes all HOA
settings to the AUTO mode of operation. When it is yellow, it indicates a device is in
the Hand mode of operation and is not set to Auto.
18C. ADJUST SETTINGS:
Pressing this button brings up a the Adjust Settings popup
screen.
18D. START BLEND:
Pressing this button and holding it for two seconds begins the
blend process. The system will run automatically until the blend is complete.
19. MIXER:
When this indicator is active, the mixer motor is running.
20. MAIN:
This button returns the operator to the main screen (see page 26).
Page 29