134
en | System Event Timers
17
System Event Timers
This section covers the features that involve timing, such as Entry and Exit Times, Sensor
Watch Time, and Siren Run Time.
17.1
Programming Entry/Exit Times
There are two programming locations for Entry Time 1, Entry Time 2, Exit Time for AWAY
Mode, and Entry Guard Time for STAY Mode.
The first location of the timer allows you to set the timer in increments of 1 sec. The sec
location allows you to set the timer in increments of 16 sec. Add these two locations together
for the total time.
Example
To set the Entry Time to 18 sec, program Location 466 as 2 (2 x 1 sec = 2 sec) and Location
467 as 1 (1 x 16 sec = 16 sec) for a total time of 18 sec (2 + 16 =18).
17.2
Entry Time 1
Item
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
You can program Entry Time 1 from 0 to 255 sec in increments of 1 sec. Entry Time 1 is the
delay time used by the Delay-1 Zones.
See also
–
17.3
Entry Time 2
Item
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
You can program Entry Time 2 from 0 to 255 sec in increments of 1 sec. Entry Time 2 is the
delay time used by Delay-2 Zones.
17.4
Exit Time
Item
Increments of 1 sec. (0 to 15 sec.)
Increments of 16 sec. (0 to 240 sec.)
You can program the Exit Time from 0 to 255 sec in increments of 1 sec. When arming the
system in AWAY Mode, the codepad beeps during Exit Time until the final 10 sec, when the
codepad sounds one continuous beep to indicate the end of Exit Time is near.
The remote codepad always sounds one short beep at the end of Exit Time when arming in
STAY Mode1 or STAY Mode 2.
2017.10 | 03 | F.01U.298.026
Location
0466
0467
Zone Types, page 97
Location
0468
0469
Location
0470
0471
Option
Option
Option
Installation Guide
Control Panel
Default
New
4
1
Default
New
8
2
Default
New
12
3
Bosch Security Systems, Inc.