Exit Time Restart - Bosch Solution 64 Installer's Manual

Intrusion control panel
Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Areas > Properties >
General Options
1

Exit Time Restart

2
Reset Alarm Memory On Disarm
3
Duress Allowed
4
Acknowledge All Faults
5
Single Button Arming - All On
6
Single Button Arming - Part On
7
Link To Common Area
8
Single Button Part Off
The above options are programmable per area.
1)
Enter [MENU] + [2] + [1] + [1] and select the area from the list
then press [OK].
Use the up and down arrow keys to highlight the option then
2)
press the [ON] key to enable or the [OFF] key to disable.
Exit Time Restart
Reset Alarm Memory
 Duress Allowed
Press

OK ON OFF MENU
3)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Exit Time Restart
The exit delay timer will restart (once per arming cycle) when the
same entry/exit delay zone is faulted a second time during exit delay
(eg. If an entry/exit delay zone is unsealled, restored and unsealled a
second time during exit delay = exit time restart).
Reset Alarm Memory On Disarm
Clears all alarm memories displayed on the keypad when a user
has turned the corresponding area off. If this option is not set,
alarm memory will continue to display until the user has turned the
corresponding area 'on' again.
Duress Allowed
If a user is being forced to turn off the security system under duress
they can disarm the system and initiate a silent duress alarm.
To trigger the duress alarm enter your PIN then repeat the last two
digits of your PIN before pressing [ON], [OFF], or [OK] key.
Example:
If your PIN is 2580, to send a duress report when the area is off,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].
If your PIN is 2580, to send a duress report when the area is on,
Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF].
Acknowledge All Faults
If this option has been programmed, the control panel will force a
user to acknowledge each trouble condition even though the trouble
condition has already cleared.
If this option is not programmed, any trouble condition that occurs
will not have to be acknowledged if it has already been rectified or
cleared.
Bosch Security Systems | 11/05 | BLCC110I
Single Button Arming Allowed – All On
This option allows users to simply press the ON key to turn the area
MENU 2-1-1
ON. All zones being armed must be sealled. If open and close reports
are programmed, the user ID number will report as 000.
N
N
Single Button Arming Allowed – Part On
N
This option allows users to simply press the Part On key to turn the
N
area Part On. All zones in the being armed must be sealled. If open
and close reports in Part Mode are programmed, the user ID number
Y
will report as 000.
Y
Y
Link To Common Area
N
This option causes the selected area or areas to control the common
area. If this option is not selected for an area then it will be able to
operate independant of the common area. See MENU 7-7-1 — Area
Options to enable the common area.
Single Button Part Off
This option allows users to disarm from Part Mode or Part Mode 2
simply by pressing the OFF key. This function will only work if there
are no alarms in effect, and the entry timer is not running.
Areas > Properties >
Input Options
1
2
3
4
5
6
7
8
The above options are programmable per area.
1)
2)
3)
Non Sequential Handover
With Non-Sequential entry path you can trigger handover zones in
any order provided that an entry delay zone was triggered first.
If this option is not programmed, handover zones must be triggered
in numerical sequence provided that an entry delay zone was
triggered first.
If a handover zone is triggered before an entry delay zone is triggered
an instant alarm will occur.
Solution 64 | Installer Guide | Area Programming
Non Sequential Handover (Entry Path)
Pulse Count Handover Allowed
Senior Watch
Reserved
Reserved
Reserved
Reserved
Reserved
Enter [MENU] + [2] + [1] + [2] and select the area from the list
then press [OK].
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
 Non Sequential
 Pulse Count H/Over
Senior Watch
Press

OK ON OFF MENU
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
MENU 2-1-2
Y
Y
N
N
N
N
N
N
6-3