Download Print this page

How To Change The Factory Settings - ATTACK PELLET Series Instructions For Use Manual

Voiler for combustion of wooden pellets

Advertisement

How to change the factory settings

For changing the adjustments you first step forward to desired menu/parameter. By pressing
the "+" button you can change values. O:... shows the current value, N:... can be changed to
a new value. Values can be increased with "+" button and decreased by "-" button .The „M"
button confirms your change and saves it. If you do not want to save it, press "E"button
(Exit/Escape).
Please do not make any changes until you have read through this manual.
Example:
OUTPUT OPTION
N:2
O:1
If you are using the burners boiler temperature sensor, two parameters can be adjusted. First
you select the cut-in temperature, you save this value by pressing "M"button, and now you can
change the cut-out temperature. By pressing "M" button once again, you save also this value.
Now the burner should operate within this new temperature range. The difference between cut-
in and cut-out temperature should be at least 5°C.
Returning to factory selttings
For re-establishing the factory settings, step forward to the Advanced menu and enter the
password (code). Then step forward to Settings and press „M" button. Now go to "Fact. reset"
and press the "M" button once more. This triggers the reloading of factory settings.
Here you can also save your own settings, as follows: step with "+" button to "Load settings?"
and save your settings with the "M" button. The "E" button gets you out of the menu.
Adjustment of pellet amount
Before taking the burner into operation, you have to trim its pellet supply via parameter „Pellets
trim" in Advanced menu. The thermostat must not call for heat while making this adjustment.
First set the parameter „Energy content" to the energy value your pellet supplier has indicated.
If the pellet supplier indicates 4,8 kW/kg, set the parameter to 48,etc.
Now tie the plastic bag around the outlet of the pellet feeder. Step forward to „Pellets trim" and
follow the instructions. Weight the pellets falling into the plastic bag, enter their weight in
grams via the "+/-" buttons and press "M" to save this value. This adjustment must be made
within 15 minutes, if not, the burner goes into pause mode. Please, weight the pellets very
accurately!
After adjusting the above-mentioned parameters, the control system automatically adjusts all
parameters related to the pellet supply.