Installation And Change Of The Fireproof Concrete Shaped Peaces - ATTACK DP25 STANDARD Instructions For Use Manual

Wood gasifying boiler
Hide thumbs Also See for DP25 STANDARD:
Table of Contents

Advertisement

Available languages

Available languages

EN
Installation and exchange of the heatproof shaped piece ( version 1)
The back part of the ash pan pos. 1 insert into the lower chamber and push to stop to the back
plate. Insert the front part of the ash pan pos. 2 and push to stop to the back part of the ash pan.
Put the super-structure of the ash pan pos. 3 on the ash pan and push it to stop to the rear. The ash
pan should be situated in the centre lime of the boiler at the front sight.When exchanging
damaged jet pos. 4 or cube pos. 5 , follow the next instructions: Take out the jet and the cube
/ the cube in DP35 and DP 45 only/ after the elimination of the gaskets. Then insert the new jet
eventually the cube and seal up with gasket backwardss. If it is necessary, change also the
gaskets. The jet is inserted regarding the sign on the lower part of the jet into the rear part of the
boiler.
Installation and exchange of the fireproof concrete shaped peaces (version 2)
Put the rear part
pos.1
into the lower chamber, the intagliated part backwards. It is necessary
to put it in horizontal possition and then turn it. Place it to the centre of the chamber and push it
to stop to the rear steel plate. Insert the left front part pos.2 to lower chamber, it is necessary to
insert this part horizontally and then turn it. Use the same method for the right front part of the
ash pan pos. 3. Push both the parts together to stop and then pull them to the rear part of the ash
pan.