P1 Phase of feeding the ignition fuel dose
P2 Feeding cycle
P3 Burning out phase
P4 Transition phase
P5 Photocell sensitivity
Tips for fine settings
P1
upper left: TIME OF FEEDING THE IGNITION FUEL DOSE (ignition):
The burner should contain thus much of pellets to let you see the upper edges of upper
ignition plate openings, the amount of approx. 0,2 - 0,25 l
(factory set on 75 sec.).
Every blink means 15 seconds.
P2
upper right:FEEDING CYCLE:
Factory settings are on 3,68 sec.(5x blink), adequate to about 10 kW, if the pellets with
diameter of 6mm are used and the pellet feeder is leaning under the angle of 45°.
P3
right below the P1:BURNING OUT = ventilator continues to run:
It determines the time of fan running continuation after the boiler thermostat has stopped and
the photocell cannot detect any flame. Factory settings are on 150 sec. Every blink is
adequate to 30 seconds.
P4
right below the P2:TRANSITIONAL PHASE (the heating up phase):
Time interval starting with 25 % pellet feeding after the photocell detected the flame (25%
of amount set on P2).
factory settings are on 270 sec. Every blink is adequate to 45 seconds.
P5 Photocell sensitivity.
It is pre-set from the factory, the factory settings should not be changed.