Download Print this page

Searching The Defects - ATTACK PELLET Series Instructions For Use Manual

Voiler for combustion of wooden pellets

Advertisement

Searching the defects

The appliance is stopped :
Before you disconnect the appliance form the main, please, note the parameters shown by
diodes LD1, LD2 and LD3 (fault report). This will help you in searching for the defect.
- Check if there are the pellets in the storage.
- Check if the feeder is functional (pellet feeding).
- Clean the grate.
- Turn the appliance on again.
The appliance does not start:
-
Check the boiler thermostat and safety thermostat.
- Check the main switch and burner switch on the boiler.
- Check the limit swith on boiler shutter.
- Test if the appliance is under the voltage, check the electrical connection with burner and
boiler.
- Check the fuses in the control box.
- Disconnect the appliance from the main and press the reset button on the thermal
protection. Then install the fan cover and attach the appliance to the main.
Ventilator and ignition works, but no pellets are feeded:
- The thermal protection of feeder motor can be activated. Disconnect the appliance from the
main and wait for approx. 10 minutes.
Let the professionals check the glass fuses on the appliance disconnected from the main and
let them replace if necessary (see the board with control electronics):
- Heating spiral
6,3 A ( slow fuse )
- Ventilator
800 mA ( fast fuse )
- Feeder
1,0 A ( fast fuse )
The fuel is feeded, but not ignitted:
Check
Remedy
- fuse (6,3 A) on printed circuit board (damaged)
- replace
- heating spiral (not heating)
- replace