Possible Causes Of Faults - ATTACK PELLET Series Instructions For Use Manual

Voiler for combustion of wooden pellets

Advertisement

Possible causes for faults
Fault
Possible causes
code
10
Pellet feeder does not supply enoughpellets.
Bin for pellets empty.
.
Fuse for ignition faulty.
Ignition coil faulty.
Photocell must be cleaned.
11
Pellet feeder does not supply enough pelets..
Bin for pellets empty.
Fuse for ignition faulty.
Ignition coil faulty.
The photocell must be cleaned.
12
Short-circuit or other fault
on the photocell.
13
Temperature in boiler room too high. Eliminate heat leakage.
14
Temperature sensor faulty.
15
Temperature sensor faulty.
16
Circuit board faulty.
18
Fan is running even when the burner
is in pause mode.
19
Fan does not run when it is
supposed to.
20
The fan runs too slow.
21
First ignition attempt has failed .
22
The pellet feeder is abssent .
23
Faulty pellets supply
24
Faulty pellets amount fed in.
Faulty photocell.
25
Scraper fault.
26
Scraper jamming.
Measures to take
Adjust/ trim the pellets supply.
Fill up the bin.
Replace the fuse. (6.3A).
Replace the coil. (48
Clean the photocell.
Adjust/ trim the pellets supply.
Fill up the bin.
Replace the fuse.(6.3A).
Replace the coil. (48
Clean the photocell.
Replace the photocell.
Replace the sensor.
Replace the sensor.
Replace the circuit board.
Replace the circuit board.
Replace the fan fuse (800mA); check
connections; replace the fan.
Clean fan; replace fan.
Adjust (trim) the pellet supply.
Plug in the pellet feeder.
Adjust (trim) the pellet supply.
Adjust (trim) the pellet supply.
Replace the photocell.
Check connections between scraper circuit board
and main circuit board.
Clean the grate. .
17
+/- 5%).
+/- 5%).